- Downloads
NAND: Reset chip on power-up
Some chips require a RESET after power-up (e.g. Micron MT29FxGxxxxx). The first command sent is NAND_CMD_READID. Issue a NAND_CMD_RESET in nand_scan_ident before reading the device id. Tested with an MT29F4G08AAC. Signed-off-by:Karl Beldan <karl.beldan@gmail.com> Signed-off-by:
Scott Wood <scottwood@freescale.com>